rtc: ab-eoz9: don't fail temperature reads on undervoltage notification
[ Upstream commit e0779a0d ] The undervoltage flags reported by the RTC are useful to know if the time and date are reliable after a reboot. Although the threshold VLOW1 indicates that the thermometer has been shutdown and time compensation is off, it doesn't mean that the temperature readout is currently impossible. As the system is running, the RTC voltage is now fully established and we can read the temperature. Fixes: 67075b63 ("rtc: add AB-RTCMC-32.768kHz-EOZ9 RTC support") Signed-off-by:Maxime Chevallier <maxime.chevallier@bootlin.com> Link: https://lore.kernel.org/r/20241122101031.68916-3-maxime.chevallier@bootlin.com Signed-off-by:
Alexandre Belloni <alexandre.belloni@bootlin.com> Signed-off-by:
Sasha Levin <sashal@kernel.org>