HID: hid-input: only ignore 0 battery events for digitizers
[ Upstream commit 0187c080 ] Commit 581c4484 ("HID: input: map digitizer battery usage") added handling of battery events for digitizers (typically for batteries presented in stylii). Digitizers typically report correct battery levels only when stylus is actively touching the surface, and in other cases they may report battery level of 0. To avoid confusing consumers of the battery information the code was added to filer out reports with 0 battery levels. However there exist other kinds of devices that may legitimately report 0 battery levels. Fix this by filtering out 0-level reports only for digitizer usages, and continue reporting them for other kinds of devices (Smart Batteries, etc). Reported-by:卢国宏 <luguohong@xiaomi.com> Fixes: 581c4484 ("HID: input: map digitizer battery usage") Signed-off-by:
Dmitry Torokhov <dmitry.torokhov@gmail.com> Signed-off-by:
Jiri Kosina <jkosina@suse.com> Signed-off-by:
Sasha Levin <sashal@kernel.org>