media: venus: firmware: Use correct reset sequence for IRIS2
commit 93f213b4 upstream. When starting venus with the "no_tz" code path, IRIS2 needs the same boot/reset sequence as IRIS2_1. This is because most of the registers were moved to the "wrapper_tz_base", which is already defined for both IRIS2 and IRIS2_1 inside core.c. Add IRIS2 to the checks inside firmware.c as well to make sure that it uses the correct reset sequence. Both IRIS2 and IRIS2_1 are HFI v6 variants, so the correct sequence was used before commit c38610f8 ("media: venus: firmware: Sanitize per-VPU-version"). Fixes: c38610f8 ("media: venus: firmware: Sanitize per-VPU-version") Cc: stable@vger.kernel.org Signed-off-by:Stephan Gerhold <stephan.gerhold@linaro.org> Reviewed-by:
Vikash Garodia <quic_vgarodia@quicinc.com> Reviewed-by:
Dikshita Agarwal <quic_dikshita@quicinc.com> Reviewed-by:
Bryan O'Donoghue <bryan.odonoghue@linaro.org> Reviewed-by:
Dmitry Baryshkov <dmitry.baryshkov@oss.qualcomm.com> [bod: Fixed commit log IRIS -> IRIS2] Signed-off-by:
Bryan O'Donoghue <bod@kernel.org> Signed-off-by:
Hans Verkuil <hverkuil+cisco@kernel.org> Signed-off-by:
Greg Kroah-Hartman <gregkh@linuxfoundation.org>