Commit e3339d44 authored by Jiawen Wu's avatar Jiawen Wu Committed by Greg Kroah-Hartman
Browse files

net: phy: marvell10g: fix 88x3310 power up



[ Upstream commit c7b75bea ]

Clear MV_V2_PORT_CTRL_PWRDOWN bit to set power up for 88x3310 PHY,
it sometimes does not take effect immediately. And a read of this
register causes the bit not to clear. This will cause mv3310_reset()
to time out, which will fail the config initialization. So add a delay
before the next access.

Fixes: c9cc1c81 ("net: phy: marvell10g: place in powersave mode at probe")
Signed-off-by: default avatarJiawen Wu <jiawenwu@trustnetic.com>
Reviewed-by: default avatarRussell King (Oracle) <rmk+kernel@armlinux.org.uk>
Signed-off-by: default avatarDavid S. Miller <davem@davemloft.net>
Signed-off-by: default avatarSasha Levin <sashal@kernel.org>