Commit e0134bbb authored by Christian Lamparter's avatar Christian Lamparter Committed by Greg Kroah-Hartman
Browse files

p54: fix sequence no. accounting off-by-one error



commit 3b5c5827 upstream.

P54_HDR_FLAG_DATA_OUT_SEQNR is meant to tell the
firmware that "the frame's sequence number has
already been set by the application."

Whereas IEEE80211_TX_CTL_ASSIGN_SEQ is set for
frames which lack a valid sequence number and
either the driver or firmware has to assign one.

Yup, it's the exact opposite!

Signed-off-by: default avatarChristian Lamparter <chunkeey@googlemail.com>
Signed-off-by: default avatarJohn W. Linville <linville@tuxdriver.com>
Signed-off-by: default avatarGreg Kroah-Hartman <gregkh@suse.de>