media: ti-vpe: vip: Add scaler support
Adding support for the scaler unit. Since there is only one scaler unit shared between 2 ports a design decision was made that only one active port would have access to the scaler unit. The other port would behave as usual relying of the sensor capability to provide different frame sizes. When a device node is opened if the scaler unit is unassigned (i.e. available) then is assigned to that port only if that port is not configured for multiple streams already. Once the scaler unit is made available subsequent try/set format will assume scaling is part of the data path. As before given the output format the frame size is constraint to vpdma alignment restriction. (i.e. bytes per line must be 16 bytes aligned). As usual, v4l2 application using this device must make sure to pay attention to the returned width, height, bytesperline and sizeimage buffer parameters to behave properly. For example a 600x400 in NV12 format will yield a 608x400 frame size instead because 600 is not divisible by 16 the closest value is 608. Signed-off-by:Benoit Parrot <bparrot@ti.com> Signed-off-by:
Jyri Sarha <jsarha@ti.com>