arm64: dts: qcom: x1e80100: Apply consistent critical thermal shutdown
[ Upstream commit 03f2b8ee ] The firmware configures the TSENS controller with a maximum temperature of 120°C. When reaching that temperature, the hardware automatically triggers a reset of the entire platform. Some of the thermal zones in x1e80100.dtsi use a critical trip point of 125°C. It's impossible to reach those. It's preferable to shut down the system cleanly before reaching the hardware trip point. Make the critical temperature trip points consistent by setting all of them to 115°C and apply a consistent hysteresis. The ACPI tables also specify 115°C as critical shutdown temperature. Cc: stable@vger.kernel.org Fixes: 4e915987 ("arm64: dts: qcom: x1e80100: Enable tsens and thermal zone nodes") Signed-off-by:Stephan Gerhold <stephan.gerhold@linaro.org> Reviewed-by:
Johan Hovold <johan+linaro@kernel.org> Reviewed-by:
Konrad Dybcio <konrad.dybcio@oss.qualcomm.com> Link: https://lore.kernel.org/r/20250219-x1e80100-thermal-fixes-v1-2-d110e44ac3f9@linaro.org Signed-off-by:
Bjorn Andersson <andersson@kernel.org> Signed-off-by:
Sasha Levin <sashal@kernel.org>