Commit 2b7cbd98 authored by Lukas Stockmann's avatar Lukas Stockmann Committed by Alexandre Belloni
Browse files

rtc: pcf85063: do a SW reset if POR failed

Power-on Reset has a documented issue in PCF85063, refer to its datasheet,
section "Software reset":

"There is a low probability that some devices will have corruption of the
registers after the automatic power-on reset if the device is powered up
with a residual VDD level. It is required that the VDD starts at zero volts
at power up or upon power cycling to ensure that there is no corruption of
the registers. If this is not possible, a reset must be initiated after
power-up (i.e. when power is stable) with the software reset command"

Trigger SW reset if there is an indication that POR has failed.

Link: https://www.nxp.com/docs/en/data-sheet/PCF85063A.pdf


Signed-off-by: default avatarLukas Stockmann <lukas.stockmann@siemens.com>
Signed-off-by: default avatarAlexander Sverdlin <alexander.sverdlin@siemens.com>
Link: https://lore.kernel.org/r/20250120093451.30778-1-alexander.sverdlin@siemens.com


Signed-off-by: default avatarAlexandre Belloni <alexandre.belloni@bootlin.com>
parent a4193578