Commit 2416cec8 authored by Jonathan Santos's avatar Jonathan Santos Committed by Jonathan Cameron
Browse files

iio: adc: ad7768-1: set MOSI idle state to prevent accidental reset



Datasheet recommends Setting the MOSI idle state to high in order to
prevent accidental reset of the device when SCLK is free running.
This happens when the controller clocks out a 1 followed by 63 zeros
while the CS is held low.

Check if SPI controller supports SPI_MOSI_IDLE_HIGH flag and set it.

Fixes: a5f8c7da ("iio: adc: Add AD7768-1 ADC basic support")
Signed-off-by: default avatarJonathan Santos <Jonathan.Santos@analog.com>
Reviewed-by: default avatarMarcelo Schmitt <marcelo.schmitt@analog.com>
Link: https://patch.msgid.link/c2a2b0f3d54829079763a5511359a1fa80516cfb.1741268122.git.Jonathan.Santos@analog.com


Signed-off-by: default avatarJonathan Cameron <Jonathan.Cameron@huawei.com>
parent 8236644f