Commit a1594162 authored by choongryeol.lee's avatar choongryeol.lee Committed by Iliyan Malchev
Browse files

mako: power: pm8921-bms: use shutdown soc if it is within limits

When a strong battery is removed, it was seen that the battery voltage
lines on the phone take about five to six seconds to go below 2.1volts
where the pmic resets all the battery backed registers.

If a new battery is plugged in within this time the driver will force
the shutdown soc on this battery which is incorrect.

Compare the shutdown soc with the calculated soc and if they are
different than a configurable limit, simply discard the shutdown soc
and use the calculated soc.

Change-Id: Ic1ce32c78346e7310b54087b03b2ee24ad6715b7
parent 94f1ec36