Commit 5b5868ef authored by Prasad Sodagudi's avatar Prasad Sodagudi Committed by Sridhar Gujje
Browse files

leds: pm8xxx: Enable PWM LPG banks based on max current



The current design enables PWM LPG high bank with out
checking the max current. So enable PWM LPG low bank when max
current configured as 4mA and enable PWM LPG high bank when
the max current configured as 8mA. Enabled both PWM LPG low bank
and PWM LPG high bank when max current configure as 12mA.

CRs-Fixed: 486318
Change-Id: I6686ed85d78fa55f08491a47c10581407e0cd70e
Signed-off-by: default avatarPrasad Sodagudi <psodagud@codeaurora.org>
Signed-off-by: default avatarSridhar Gujje <sgujje@codeaurora.org>